Waste Incinerator Equipment Manufacturer   

   
    Medical Waste / Animal Pet Cremation / Solid Waste Incineration   

  

       

  


 



 

Tel: +86-25-8461 0201
Fax: +86-25-8461 0406
Email: sales@clover-incinerator.com
Skype: clover-incinerator
Twitter: twitter.com/hiclovercom
Facebook: www.facebook.com/hiclover

 

 Incinerator Project Case

Incinerator YD-30 for Australia

Incinerator YD-50 for Moldova

Incinerator YD-100 for Iraq

Incinerator YD-150 for Morocco

Incinerator YD-300 for Somalia

Incinerator YD-500 for Vietnam


 Medical Waste Incinerators

30kgs per hour&Model YD-30

50kgs per hour&Model YD-50

100kgs per hour&Model YD-100

150kgs per hour&Model YD-150

300kgs per hour&Model YD-300

500kgs per hour&Model YD-500
 

 

Medical Waste Incinerator

Treatment Capacity:30kgs per hour

Pусский: www.hiclover.ru|中文: www.haiwo.net 
Photo Gallery: www.eclover.net | Clover News: www.incinerator.info
        

  Medical Waste Incinerator YD Model is our classic product for market. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry scrubber (smoke filter chamber) with reasonable project budget. For the cleaner emission require, we accept custom made wet scrubber for incinerator and this will be also our next working by focusing on emission technical.

 

Model YD-30 
Burning Rate  30 kgs/hour
Feed Capacity 60 kgs
Primary Combustion Chamber 360 Liters
Secondary Combustion Chamber 200 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 10.2--19.8 kg/hour
Gas Consumption (Natural Gas) 9.8--20 m3/hour
Internal Dimensions 100 x 60 x 60cm (primary chamber)
External Dimensions 145 x 90 x 260cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 200 Liters
Door Opening 48 x 60cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 2300 kgs
Operation Technical Specifications
Primary Chamber Temperature 800--1000
Secondary Chamber Temperature 1000-1200
Residency Time 2.0 Sec.
Burning Efficiency 98%
Waste Lower Calorific Power 3000Kcal

 

TECHNICAL SPECIFICATIONS: PYROLYTIC INCINERATOR
Parameter Compliance
Type of Waste To treat medical waste, categories A,B,C,D,E
Type of Incinerator Pyrolytic
Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg
Loading Manual, Batch Load
De Ashing Automatic or Manual batch de ashing
The incinerator must avoid the release of black smoke and fine dust during the loading
Primary chamber capacity 2-3 m³
The insulation of the combustion chamber should be composed of refractory bricks, having a higher content of aluminium and insulates,
The plate of combustion in carborundum avoiding the fixing of glass and slags
Hours of operation /Day >10 hrs
Max Operating Temperatures 1400 °C
Normal Operating Temperatures(Primary) >850 °C
Operating Temperature(Secondary) >1100 °C
It should have digital temperatures regulator( Temperatures regulator in digital watch)
Carbon content of ashes <2%
The installation should be completely free from visible smoke as well as offensive odours
Residence time in second chamber 2 second minimum
The internal diameter of the Chimney :Ø 400
Height of stack >8m
Burner operation Automatic On/Off
Fuel Diesel
Fuel consumption at raed capacity >7kg waste /ltr
Electricity consumption <2kW at rated capacity
Operating Voltage 220 – 240V AC 50Hz
Spare parts Supply for 1 year quoted as option
Consumables Supply for 1 year of operation to be mentioned as option
Warranty Parts and service support: 1 year minimum post comissioning
Service support <72 hours
Emission standard Compliance BS3316 or equivqlent standard
Process filtering system Scruber to be mentioned as option
CE Manufacturing Compliance BS EN 746-2-1997
Design Specification Type A,B,C,D,and E of medical waste
Installation and Comissioning Included in condition of supply
Training in preventive and curative maintenance and use of the incinerator Operator training inclusive in offer
Capacity to treat Plastic Not less than 40% by weight